Reliable sample identification and traceability using RFID identifiers
Clear sample allocation in the laboratory with RFID data transfer
New 2D barcode, documenting batch information including expiry date
Batch certificates directly available - also for printing - on the RFID tag of the cuvette test box
Accurate adjustment of lab/process measurement values using LINK2SC
Simple, reliable transfer of data to networks via Ethernet connection or USB stick
The DR 3900 Spectrophotometer with RFID, IBR+, AQA+ and LINK2SC delivers maximum reliability at every stage of the water analysis process.
To find out more about the new features of the new DR 3900, please continue reading.
How the DR 3900 works
SAMPLING & SAMPLE PREPARATION
What, when, where and who
Safety right from the start
RFID encoding of each sample
Reliable identification of samples
Assured traceability of samples
RFID data transfer from the sample to the spectrophotometer
Samples must be traceable to generate reliable results in the field of water analysis. This traceability can be guaranteed by consistently logging all relevant sample data via RFID (Radio Frequency Identification).
ANALYSIS
Increased reliability
The DR 3900 photometer automatically identifies from the new 2D barcode on HACH LANGE cuvette tests whether there is a new cuvette test available or if an existing method must be updated. If so, the required calibration data are now directly available from the RFID tag on the cuvette packaging. The new 2D barcode also details the batch number and the expiry date of the reagents. If the expiry date has already passed, an automatic warning will be issued.
QUALITY ASSURANCE
Real-time communication between lab and process with LINK2SC
The LINK2SC connection between the photometer and the SC controller guarantees that analysis is transparent, facilitating direct comparison between laboratory and process results. The data from the laboratory is returned to the controller via Ethernet and the process probe is adjusted (where necessary).
Easy adjustment of lab and process data with LINK2SC
Bi-directional data streams
If necessary, immediate matrix correction of the process probe
AQA measurements can now be defined and documented in the photometer itself. Current batch certificates (for GMP/GLP documentation purposes) can be found on the RFID tag of the cuvette test packaging. They can be retrieved immediately on the DR 3900 photometer and printed out. Measurement values are saved using the established ADDISTA system with standard and round robin solutions. Quality control cards can now be created and maintained in the spectrophotometer.
DOCUMENTATION
Data transfer via Ethernet connection or USB stick
The DR 3900 Spectrophotometer can be networked, supporting the efficient documentation of analysis data in the various connected systems. The spectrophotometer also helps to make sure that measurement values are correctly interpreted and classified.
The DR 3900 delivers comprehensive reliable water analysis results at every stage of the water analysis process.