For the download of technical documentation we ask you for name and e-mail address, downloads from the category information are excluded naturally.
The following documents match your search:
| Application |
|
1
|
|
LANGE cuvette tests used by the professionals for 40 years
|
| |
The document reports of the advatages of the LANGE cuvette tests. Author: Dipl.-Ing. Petra Puetz, HACH LANGE Lab product specialist. The launch of the world’s first ready-to-use reagent packages for photometric
analysis in the 1960s had a substantial effect on environmental analysis. Today LANGE cuvette tests and photometers are indispensable elements of
operational analysis. Innovations such as 10-fold rotational measurement
have simplified analysis even further and made it more reliable. Quality
assurance procedures (analytical quality assurance ADDISTA, round robin tests) are carried out and documented. The correct processing of used reagents in HACH LANGE’s own certified environment centre completes the LANGE cuvette test-system. 8 pages
|
| |
Date: 2010-05-28
|
1.16 MB
Download
|
|
|
2
|
|
Application Instruction: Determination of chlorophyll with DR 5000
|
| |
Application APP-PHM-0002 describes the measurement of chlorophyll and offers an additional program for the spectrophotometer DR 5000. Save the ZIP file to your PC or USB memory stick. Unpack the ZIP file and save the files to the USB memory stick with checkbox “Use folder names” clicked. You will get a folder with the program data and a printable version of the application as pdf-file.
|
| |
Date: 2009-03-12
|
89.1 KB
Download
|
|
|
3
|
|
COD, Cost effective refilling of activated carbon filter
|
| |
The leachate from a landfill in North Rhine-Westphalia, Germany, used to
be transported by road tanker to the nearest sewage treatment plant. Since
1998 a biological treatment plant has been in operation, which has now
handled more than 650,000 m3 of leachate, at a maximum rate of 350 m3/day.
Four activated carbon filters, each filled with 20 m3, handle the residual COD
load. The wastewater is fed into them in a sequence that depends on how
long the activated carbon has been in use. A freshly regenerated filter discharges treated wastewater with a COD concentration of about 50 mg/l;
this is well below the limit of 400 mg/l and is therefore a major cost factor.
This can be avoided with the help of the COD cuvette test. 4 pages
|
| |
Date: 2008-12-18
|
763 KB
Download
|
|
| Information |
|
4
|
|
DR 5000 UV-VIS Spectrophotometer: Simply more
|
| |
DR 5000 UV-VIS Spectrophotometer: More than a photometer; More methods, more parameters; More applications; More efficiency; the new DR 5000 spectrophotometer features more than 200 pre-programmed HACH and LANGE tests for water analysis, a touchscreen display, easy handling; information and technical data; 8 pages, laboratory analysis,
|
| |
Date: 2010-05-28
|
3.66 MB
Download
|
|
| Quality data |
|
5
|
|
Certificate from "Biroul Roman de Metrologie Legala" for DR2800 and DR5000
|
| |
Certificate from "Biroul Roman de Metrologie Legala" for DR2800 and DR5000
|
| |
Date: 2006-05-06
|
1.19 MB
Download
|
|
| Software |
|
6
|
|
DR 5000 spectrophotometer version: 1.08 / 10 / 63
|
| |
Instrument Version 1.08
Program Versions:
HACH 10: New tests.
HACH LANGE 63: New factors for Phosphate cuvette test LCK348 + LCK350 New test for COD for samples with high chloride concentrations: LCK1014 , measuring range: 100-2000 mg/l
Save the ZIP file to your PC or USB memory stick.
Unpack the ZIP file and save the files to the an empty USB memory stick.
Please find more information in the README file enclosed in the download and in the manual chapter 6.8.2 - Update of the instrument software.
|
| |
Date: 2010-01-15
|
1.68 MB
Download
|
|
| Technical documents |
|
7
|
|
Manual: DR 5000 Spectrophotometer (Edition 3)
|
| |
Detailed manual for the Spectrophotometer DR 5000 with pictures, screenshots and step by step instructions.
|
| |
Date: 2008-03-06
|
2.39 MB
Download
|
|
|
8
|
|
Manual HACH DATA TRANS Data collection software for spectrophotometers
|
| |
HACH DATA TRANS is a Windows-based PC program dedicated for use with the DR 5000 and DR 2800 spectrophotometer. With the HACH DATA TRANS the method is edited and started from the instrument. Measurements are collected, displayed and saved by the software. HACH DATA TRANS is a powerful data archiving tool, which enables you to access your stored results and curves in a flash via user-programmable requests. You can consult the database and filter and sort the archived results by date, program type etc. providing the information you need at a glance; 19 pages
|
| |
Date: 2006-08-01
|
1.27 MB
Download
|
|
|
9
|
|
User Manual drinking water analysis, supplementary software LZV 571 - DR 5000
|
| |
Description and how to measure with DR 5000 the parameter Nitrate, organic load and color by direct absorption without reagents
|
| |
Date: 2006-05-18
|
266 KB
Download
|
|
|
10
|
|
User Manual brewerie analysis, supplementary software LZV 570 - DR 5000
|
| |
Detailed description of the application brewrey analysis with DR 5000, software supported.
|
| |
Date: 2006-05-18
|
609 KB
Download
|
|
|
11
|
|
User Manual drinking water analysis, supplementary software LZV 571 - DR 5000 (Edition 2)
|
| |
Description and how to measure with DR 5000 the parameter Nitrate, organic load and color by direct absorption without reagents
|
| |
Date: 2006-05-04
|
285 KB
Download
|
|
|
12
|
|
User Manual brewerie analysis, supplementary software LZV 570 - DR 5000 (Edition 2)
|
| |
Detailed description of the application brewrey analysis with DR 5000, software supported.
|
| |
Date: 2006-05-04
|
588 KB
Download
|
|
| Working procedure |
|
13
|
|
Procedure Manual for Spectrophotometer DR 5000
|
| |
The Procedure Manual describes all photometrical procedures in detail that can be measured with the DR 5000 (Alachlor, Aluminum, Ammonia, Arsenic, Atrazine, Barium, Benzotriazole Tolyltriazole, Boron, Bromine, Cadmium, Chloramine, Chloride, Chlorine Dioxide Totale, Chromium hexavalent, Cobalt, Color, Copper, Cyanide, Fluoride, Formaldehyde, Hardness, Hydrazine, Iodine, Iron Ferrous Total, Lead, Manganese, Mercury, Molybdän, Nickel, Nitrat, Nitrit, Nitrogen Ammonia, Organic Constituents, Oxygene dissolved, Scavengers, Ozone, Quaternary Ammonium Compounds, Selenium, Silica, Silver, Sulfate, Sulfide, Sulfite, Surfactants, Suspended Solids, Tannin Lignin, TPH, Trihalomethane, Volatile Acids, Zinc)
|
| |
Date: 2008-07-16
|
5.44 MB
Download
|
|
|
14
|
|
Working procedure LCK 387 TOC, purging method, cuvette test
|
| |
Measuring range 300-3000 mg/l TOC
|
| |
Date: 2007-09-20
|
150 KB
Download
|
|
|
15
|
|
Working procedure LCK 386 TOC, purging method, cuvette test
|
| |
Measuring range 30-300 mg/l TOC
|
| |
Date: 2007-09-20
|
141 KB
Download
|
|
|
16
|
|
Working procedure LCK 385 TOC, purging method, cuvette test
|
| |
Measuring range 3-30 mg/l TOC
|
| |
Date: 2007-09-20
|
141 KB
Download
|
|
|
17
|
|
Working procedure LCK 387 TOC, purging method, cuvette test
|
| |
Measuring range 300-3000 mg/l TOC
|
| |
Date: 2007-06-01
|
149 KB
Download
|
|
|
18
|
|
Working procedure LCK 386 TOC, purging method, cuvette test
|
| |
Measuring range 30-300 mg/l TOC
|
| |
Date: 2007-06-01
|
140 KB
Download
|
|
|
19
|
|
Working procedure LCK 385 TOC, purging method, cuvette test
|
| |
Measuring range 3-30 mg/l TOC
|
| |
Date: 2007-06-01
|
140 KB
Download
|
|
|
20
|
|
Working procedure LCK 014 COD cuvette test
|
| |
measuring range 1000-10,000 mg/l
|
| |
Date: 2007-06-01
|
202 KB
Download
|
|
|
21
|
|
Working procedure LCK 387 TOC, purging method, cuvette test
|
| |
Measuring range 300-3000 mg/l TOC
|
| |
Date: 2005-10-17
|
149 KB
Download
|
|
|
22
|
|
Working procedure LCK 386 TOC, purging method, cuvette test
|
| |
Measuring range 30-300 mg/l TOC
|
| |
Date: 2005-10-17
|
140 KB
Download
|
|
|
23
|
|
Working procedure LCK 114 COD cuvette test
|
| |
measuring range 150-1000 mg/l
|
| |
Date: 2005-10-17
|
195 KB
Download
|
|
|
24
|
|
Working procedure LCK 385 TOC, purging method, cuvette test
|
| |
Measuring range 3-30 mg/l TOC
|
| |
Date: 2005-10-17
|
140 KB
Download
|
|
|
25
|
|
Working procedure LCK 014 COD cuvette test
|
| |
measuring range 1000-10,000 mg/l
|
| |
Date: 2005-10-17
|
202 KB
Download
|
|