Water Quality Monitoring 40 Metres Below the Sea bed
|
| |
Natural groundwater collected around the tunnels operated by Eurotunnel is
continuously monitored before being pumped to the coast and discharged
into the sea. Six multiparameter water quality monitoring systems have been
custom-designed by HACH LANGE to ensure that there is no potential for
harmful water to enter the pipelines. Each monitoring system is connected to a sophisticated data collection and alarm system that is able to divert water into vast underground sumps if alarm conditions occur. To-date, no such emergency has taken place. Commenting on the new monitoring system is the Eurotunnel Senior Technician / Project Manager Michael Edwards and the Eurotunnel maintainance staff. 4 pages
|
| |
Date: 2008-10-20
|
956 KB
Download
|
|
|
2
|
|
On field experience pHD-S sc
|
| |
Use of the pHD-S sc in industrial waste water
|
| |
Date: 2008-08-06
|
470 KB
Download
|
|
| Information |
|
3
|
|
pHD-S sc: digital differential electrode for pH and redox
|
| |
Product information, PROCESS ANALYSES, Electrochemistry, 2 pages: pHD-S sc, description, benefits, technical data, ordering information
|
| |
Date: 2010-07-08
|
252 KB
Download
|
|
|
4
|
|
SC 100 / SC 1000, controller
|
| |
SC controller: One for all; The standard platform for all probes and analysers
Abstract: SC 100 / SC 1000, benefit of the technology, principle, modification for all probes, SC network, technical data, order information; 12 pages
|
| |
Date: 2010-05-28
|
1.86 MB
Download
|
|
| Software |
|
5
|
|
Software: Available EDD (Electronic Device Description) files for SI792 2-wire transmitter
|
| |
Available EDD files for SI792 (SI792 Profibus PA) 2-wire Transmitter (use of Simatic PDM 6.0)
|
| |
Date: 2008-07-16
|
126 KB
Download
|
|
|
6
|
|
Software: Available EDD (SC 1000) files SIMATIC PDM V6.0
|
| |
Available EDD (Electronic Device Description) SC 1000 files for SIMATIC PDM V6.0
|
| |
Date: 2008-07-16
|
1.13 MB
Download
|
|
|
7
|
|
Software: Available EDD (SC100) files SIMATIC PDM V6.0
|
| |
Software: Available EDD (Electronic Device Description) files for SC 100 (SIMATIC PDM V6.0)
|
| |
Date: 2008-07-16
|
854 KB
Download
|
|
|
8
|
|
Software: Available GSD files for SI792 2-wire transmitter
|
| |
Available GSD files for SI792 (SI792PA) 2-wire Transmitter (Profibus)
|
| |
Date: 2008-07-16
|
2.16 KB
Download
|
|
| Technical documents |
|
9
|
|
Mounting instruction6 E-Chem
|
| |
Mounting instruction6 E-Chem
(LZX914.99.32200)
|
| |
Date: 2010-03-24
|
1.94 MB
Download
|
|
|
10
|
|
Mounting instruction5 E-Chem
|
| |
Mounting instruction5 E-Chem
(LZX914.99.31200)
|
| |
Date: 2010-03-24
|
441 KB
Download
|
|
|
11
|
|
Mounting instruction4 E-Chem
|
| |
Mounting instruction4 E-Chem
(LZX914.99.12200)
|
| |
Date: 2010-03-24
|
239 KB
Download
|
|
|
12
|
|
Mounting instruction3 E-Chem
|
| |
Mounting instruction3 E-Chem
(LZX914.99.11200)
|
| |
Date: 2010-03-24
|
253 KB
Download
|
|
|
13
|
|
Mounting instruction2 E-Chem
|
| |
Mounting instruction2 E-Chem
(LZX914.99.02200)
|
| |
Date: 2010-03-24
|
51.7 KB
Download
|
|
|
14
|
|
Mounting instruction1 E-Chem
|
| |
Mounting instruction1 E-Chem
(LZX914.99.01200)
|
| |
Date: 2010-03-24
|
226 KB
Download
|
|
|
15
|
|
Manual sc1000
|
| |
User Manual sc1000
|
| |
Date: 2009-06-18
|
3.82 MB
Download
|
|
|
16
|
|
Sensor Insertion (Ball Valve) Mounting (5646300, 5646350, 5646400, 5646450, MH73M4MZ)
|
| |
Instruction Sheet: Sensor Insertion (Ball Valve) Mounting (5646300, 5646350, 5646400, 5646450, MH736M4MZ)
for pHD
|
| |
Date: 2009-05-13
|
777 KB
Download
|
|
|
17
|
|
Manual: pHD sc Digital Differential pH/ORP Sensors
|
| |
Manual: pHD sc Digital Differential pH/ORP Sensors
|
| |
Date: 2008-12-11
|
624 KB
Download
|
|
|
18
|
|
Manual sc60
|
| |
Manual sc60
|
| |
Date: 2008-12-11
|
1.97 MB
Download
|
|
|
19
|
|
Manual sc100
|
| |
Manual sc100
|
| |
Date: 2008-12-11
|
1.83 MB
Download
|
|
|
20
|
|
Installation instructions tank rim mount for LDO process and E-Chem Sensors
|
| |
Overview from installation kits.
|
| |
Date: 2008-08-06
|
3.33 MB