HACH LANGE   Home | Contact | Email | Countries  
 Cart    Disposal  
Documents
For the download of technical documentation we ask you for name and e-mail address, downloads from the category information are excluded naturally.

The following documents match your search:

Application
1   LANGE cuvette tests used by the professionals for 40 years
  The document reports of the advatages of the LANGE cuvette tests. Author: Dipl.-Ing. Petra Puetz, HACH LANGE Lab product specialist. The launch of the world’s first ready-to-use reagent packages for photometric analysis in the 1960s had a substantial effect on environmental analysis. Today LANGE cuvette tests and photometers are indispensable elements of operational analysis. Innovations such as 10-fold rotational measurement have simplified analysis even further and made it more reliable. Quality assurance procedures (analytical quality assurance ADDISTA, round robin tests) are carried out and documented. The correct processing of used reagents in HACH LANGE’s own certified environment centre completes the LANGE cuvette test-system. 8 pages
  Date: 2007-09-18 1.16 MB PDF Download
2   COD, Cost effective refilling of activated carbon filter
  The leachate from a landfill in North Rhine-Westphalia, Germany, used to be transported by road tanker to the nearest sewage treatment plant. Since 1998 a biological treatment plant has been in operation, which has now handled more than 650,000 m3 of leachate, at a maximum rate of 350 m3/day. Four activated carbon filters, each filled with 20 m3, handle the residual COD load. The wastewater is fed into them in a sequence that depends on how long the activated carbon has been in use. A freshly regenerated filter discharges treated wastewater with a COD concentration of about 50 mg/l; this is well below the limit of 400 mg/l and is therefore a major cost factor. This can be avoided with the help of the COD cuvette test. 4 pages
  Date: 2007-02-21 763 KB PDF Download
Information
3   DR 5000 UV-VIS Spectrophotometer: Simply more
  DR 5000 UV-VIS Spectrophotometer: More than a photometer; More methods, more parameters; More applications; More efficiency; the new DR 5000 spectrophotometer features more than 200 pre-programmed HACH and LANGE tests for water analysis, a touchscreen display, easy handling; information and technical data; 8 pages, laboratory analysis,
  Date: 2005-07-13 3.28 MB PDF Download
Quality data
4   Certificate from "Biroul Roman de Metrologie Legala" for DR2800 and DR5000
  Certificate from "Biroul Roman de Metrologie Legala" for DR2800 and DR5000
  Date: 2006-05-06 1.19 MB PDF Download
Software
5   Software: DR 5000 spectrophotometer version: 1.07 / 07b / 58
  Instrument version 1.07

We continuously maintain and update our photometer DR 5000. We have integrated some new functions:
  • recognition of printer PD24 (item-no.: 5835900.00)
  • menue guided use of verification kit (LZV537)
  • instrument backup (reset of instrument for instrument service)
  • save single test as *.lst and transfer to second instrument
  • service-time reminder
  • HACH DATA TRANS auto send/remote
  • scanner and USB keyboard for fast sample ID
  • sipper on/off while using cuvette test
  • send data – curve or table separately
  • error messages with indices
  • rename timer to process-timer
  • screen and sound - timer long
  • color measurement ADMI
  • new languages for the user interface are available
Program Versions:
HACH 31 New methods Color ADMI and Color LR
HACH LANGE 58 New tests, new calibration LCK349

optional: reagent blank for several LCK tests

See also revised manual DR 5000 - English.
See also revised manual DR 5000 - German.
See also revised manual DR 5000 - French.
See also revised manual DR 5000 - Italian.
See also revised manual DR 5000 - Spanish.
See also revised manual DR 5000 - Dutch.
See also revised manual DR 5000 - Danish.

Save the ZIP file to your PC or USB memory stick.
Unpack the ZIP file and save the files to the USB memory stick.
Please find more information in the README file enclosed in the download.
  Date: 2008-03-11 1.68 MB PDF Download
Technical documents
6   Manual: DR 5000 Spectrophotometer (Edition 3)
  Detailed manual for the Spectrophotometer DR 5000 with pictures, screenshots and step by step instructions.
  Date: 2008-03-05 2.39 MB PDF Download
7   Manual HACH DATA TRANS Data collection software for spectrophotometers
  HACH DATA TRANS is a Windows-based PC program dedicated for use with the DR 5000 and DR 2800 spectrophotometer. With the HACH DATA TRANS the method is edited and started from the instrument. Measurements are collected, displayed and saved by the software. HACH DATA TRANS is a powerful data archiving tool, which enables you to access your stored results and curves in a flash via user-programmable requests. You can consult the database and filter and sort the archived results by date, program type etc. providing the information you need at a glance; 19 pages
  Date: 2006-08-01 1.27 MB PDF Download
8   User Manual brewerie analysis, supplementary software LZV 570 - DR 5000 (Edition 2)
  Detailed description of the application brewrey analysis with DR 5000, software supported.
  Date: 2006-04-10 588 KB PDF Download
9   User Manual drinking water analysis, supplementary software LZV 571 - DR 5000 (Edition 2)
  Description and how to measure with DR 5000 the parameter Nitrate, organic load and color by direct absorption without reagents
  Date: 2006-04-10 285 KB PDF Download
10   User Manual brewerie analysis, supplementary software LZV 570 - DR 5000
  Detailed description of the application brewrey analysis with DR 5000, software supported.
  Date: 2005-11-22 609 KB PDF Download
11   User Manual drinking water analysis, supplementary software LZV 571 - DR 5000
  Description and how to measure with DR 5000 the parameter Nitrate, organic load and color by direct absorption without reagents
  Date: 2005-11-22 266 KB PDF Download
Working procedure
12   Procedure Manual for Spectrophotometer DR 5000
  The Procedure Manual describes all photometrical procedures in detail that can be measured with the DR 5000 (Alachlor, Aluminum, Ammonia, Arsenic, Atrazine, Barium, Benzotriazole Tolyltriazole, Boron, Bromine, Cadmium, Chloramine, Chloride, Chlorine Dioxide Totale, Chromium hexavalent, Cobalt, Color, Copper, Cyanide, Fluoride, Formaldehyde, Hardness, Hydrazine, Iodine, Iron Ferrous Total, Lead, Manganese, Mercury, Molybdän, Nickel, Nitrat, Nitrit, Nitrogen Ammonia, Organic Constituents, Oxygene dissolved, Scavengers, Ozone, Quaternary Ammonium Compounds, Selenium, Silica, Silver, Sulfate, Sulfide, Sulfite, Surfactants, Suspended Solids, Tannin Lignin, TPH, Trihalomethane, Volatile Acids, Zinc)
  Date: 2008-07-16 5.44 MB PDF Download
13   Working procedure LCK 385 TOC, purging method, cuvette test
  Measuring range 3-30 mg/l TOC
  Date: 2007-09-20 141 KB PDF Download
14   Working procedure LCK 386 TOC, purging method, cuvette test
  Measuring range 30-300 mg/l TOC
  Date: 2007-09-20 141 KB PDF Download
15   Working procedure LCK 387 TOC, purging method, cuvette test
  Measuring range 300-3000 mg/l TOC
  Date: 2007-09-20 150 KB PDF Download
16   Working procedure LCK 014 COD cuvette test
  measuring range 1000-10,000 mg/l
  Date: 2007-06-01 202 KB PDF Download
17   Working procedure LCK 385 TOC, purging method, cuvette test
  Measuring range 3-30 mg/l TOC
  Date: 2007-06-01 140 KB PDF Download
18   Working procedure LCK 386 TOC, purging method, cuvette test
  Measuring range 30-300 mg/l TOC
  Date: 2007-06-01 140 KB PDF Download
19   Working procedure LCK 387 TOC, purging method, cuvette test
  Measuring range 300-3000 mg/l TOC
  Date: 2007-06-01 149 KB PDF Download
20   Working procedure LCK 014 COD cuvette test
  measuring range 1000-10,000 mg/l
  Date: 2005-10-17 202 KB PDF Download
21   Working procedure LCK 114 COD cuvette test
  measuring range 150-1000 mg/l
  Date: 2005-10-17 195 KB PDF Download
22   Working procedure LCK 385 TOC, purging method, cuvette test
  Measuring range 3-30 mg/l TOC
  Date: 2005-10-17 140 KB PDF Download
23   Working procedure LCK 386 TOC, purging method, cuvette test
  Measuring range 30-300 mg/l TOC
  Date: 2005-10-17 140 KB PDF Download
24   Working procedure LCK 387 TOC, purging method, cuvette test
  Measuring range 300-3000 mg/l TOC
  Date: 2005-10-17 149 KB PDF Download